- Cable
-
-
- Connection
-
Push-in connector 2-pole
- Control gear failure rate at median useful life 35,000 h
-
7.5
%
- Control interface
-
-
- Driver/power unit/transformer
-
Power supply unit (On/Off)
- Driver included
-
Yes
- Fixation material
-
-
- Flammability mark
-
For mounting on normally flammable surfaces
- Flickering value (PstLM)
-
1
- Glow-wire test
-
Temperature 850 °C, duration 30 s
- Ingress protection code
-
IP65 | Dust penetration-protected, jet-proof
- Line Frequency
-
50 or 60
- Lumen maintenance at median useful life* 100,000 h
-
-
- Lumen maintenance at median useful life* 50,000 h
-
-
- Lumen maintenance at median useful life* 75000 h
-
-
- Mech. impact protection code
-
IK08 | 5 J vandal-protected
- Number of gear units
-
Unit
- Number of products on MCB (16 A type B)
-
18
- Protection class IEC
-
Safety class II
- Suitable for random switching
-
Yes
- Dimmable
-
No