HF-Performer III for TL-D lamps

HF-P 118 TL-D III 220-240V 50/60Hz IDC

HF-P 118 TL-D III 220-240V 50/60Hz IDC

  • An energy-efficient solution

    Product information

    Downloads

    Leaflet
    Size:578.4 kB

    See all downloads

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Information
Application code
III
Type version
IDC
Lamp type
TL-D
Number of lamps
1 piece/unit
Number of products on MCB (16 A type B) (nom.)
28
Automatic restart
Yes
Operating and Electrical
Input voltage
220 to 240 V
Input frequency
50-60 Hz
Operating frequency (nom.)
45 kHz
Ignition method
Programmed Start
Crest factor (max.)
1.7
Power factor 100% load (nom.)
0.97
Ignition time (max.)
1.5 s
Mains voltage performance (AC)
-8%-+6%
Mains voltage safety (AC)
-10%-+10%
Earth leakage current (nom.)
0.5 mA
Inrush current width
0.25 ms
Constant wattage deviation
-2%/+2%
Ballast factor (nom.)
0.93
Power losses (nom.)
2.4 W
Inrush current peak (max.)
18 A
Wiring
Connector type input terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable capacity output wires mutual (nom.)
200 pF
Connector type output terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable length hot-wiring
0.75 m
Wire strip length
8.0-9.0 mm
Dual fixture master/slave
Not applicable  [ Master/Slave oper. not applicable]
Input terminal cross section
0.50-1.00 mm²
Output terminal cross section
0.50-1.00 mm²
Cable capacity output wires to earth (nom.)
200 pF
System characteristics
Rated ballast-lamp power
18 W
Rated lamp power on TL-D
18 W
System power on TL-D
18.2 W
Lamp power on TL-D
15.8 W
Power loss on TL-D
2.4 W
Temperature
T ambient (max.)
60 °C
T ambient (min.)
-25 °C
T storage (max.)
50 °C
T storage (min.)
-40 °C
T case lifetime (nom.)
80 °C
T-Case maximum (max.)
80 °C
T-Ignition (max.)
60 °C
T-Ignition (min.)
-25 °C
Mechanical and Housing
Housing
L280X30X28
Emergency Operation
Nominal light output after 60 seconds
100% of EBLF
Battery voltage lamp ignition
186-275 V
Normal operating voltage (DC)
220-240 V
Battery voltage lamp operation
186-275
Battery voltage guaranteed operation
176-275 V
Battery voltage guaranteed ignition
186-275 V
Emergency ballast lumen factor (EBLF) (nom.)
0.7 %
Nominal light output after 5 seconds
50% of EBLF
Approval and Application
Energy efficiency index
A2 BAT
EMI 9 kHz... 30 MHz
EN55015
EMI 30 MHz... 1,000 MHz
EN55022 level B
Safety standard
IEC 61347-2-3
Performance standard
IEC 60929
Quality standard
ISO 9000:2000
Environmental standard
ISO 14001
Harmonic current emission standard
IEC 61000-3-2
EMC immunity standard
IEC 61547
Vibration standard
IEC68-2-6 F c
Bumps standard
IEC 68-2-29 Eb
Humidity standard
EN 61347-2-3 clause 11
Approval marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature marking
Yes
Emergency standard
IEC 60598-2-22
Humming and noise level
< 30 dB(A)
Product Data
Full product code
872790091158900
Order product name
HF-P 118 TL-D III 220-240V 50/60Hz IDC
EAN/UPC – product
8711500999580
Order code
91158900
Local Code
HFP118TLDIII
Numerator – quantity per pack
1
Numerator – packs per outer box
12
Material no. (12NC)
913713031266
Net weight (piece)
0.200 kg
Installation Diagrams
Performance Diagrams

Recently Viewed

    • Manage your projects with MyProjects
      Use MyProjects to create, save manage and share items and projects with you colleagues and team members.

Events    

 

 

Business Climate Summit

28-29.06.2016, London Guildhall

 

The Public Sector Show

28.06.2016, ExCeL

 

Grand Designs Live

19-23.10.2016, Birmingham NEC

 

View all events

You are now visiting our Global professional lighting website, visit your local website by going to the USA website