HF-Performer III for TL5 lamps

HF-P 280 TL5/PL-L III 220-240V 50/60Hz

HF-P 280 TL5/PL-L III 220-240V 50/60Hz

  • An energy-efficient solution

    Product information

    Downloads

    Leaflet
    Size:194.3 kB

    See all downloads

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Information
Application code
III
Type version
MK1
Lamp type
TL5-PL-L
Number of lamps
2 piece/unit
Number of products on MCB (16 A type B) (nom.)
12
Automatic restart
Yes
Operating and Electrical
Input voltage
220 to 240 V
Input frequency
50-60 Hz
Operating frequency (nom.)
45 kHz
Ignition method
Warm Start
Crest factor (max.)
1.7
Power factor 100% load (nom.)
0.99
Ignition time (max.)
1.2 s
Mains voltage performance (AC)
-8%-+6%
Mains voltage safety (AC)
-10%-+10%
Earth leakage current (nom.)
0.5 mA
Inrush current width
0.40 ms
Constant wattage deviation
-2%/+2%
Ballast factor (nom.)
1.01
Power losses (nom.)
9.64-7.45 W
Inrush current peak (max.)
40 A
Wiring
Connector type input terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable capacity output wires mutual (nom.)
200 pF
Connector type output terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable length hot-wiring
0.75 m
Wire strip length
8.0-9.0 mm
Dual fixture master/slave
Not applicable  [ Master/Slave oper. not applicable]
Input terminal cross section
0.50-1.00 mm²
Output terminal cross section
0.50-1.00 mm²
Cable capacity output wires to earth (nom.)
200 pF
System characteristics
Rated ballast-lamp power
80 W
Rated lamp power on PL-L
80 W
System power on PL-L
87.5 W
Lamp power on PL-L
80 W
Power loss on PL-L
7.5 W
Rated lamp power on TL5
80 W
System power on TL5
89.6 W
Lamp power on TL5
80 W
Power loss on TL5
9.6 W
Temperature
T ambient (max.)
60 °C
T ambient (min.)
-25 °C
T storage (max.)
50 °C
T storage (min.)
-40 °C
T case lifetime (nom.)
85 °C
T-Case maximum (max.)
85 °C
T-Ignition (max.)
60 °C
T-Ignition (min.)
-25 °C
Mechanical and Housing
Housing
L425X30X21
Emergency Operation
Nominal light output after 60 seconds
100% of EBLF
Battery voltage lamp ignition
186-275 V
Normal operating voltage (DC)
220-240 V
Battery voltage lamp operation
176-275
Battery voltage guaranteed operation
176-275 V
Battery voltage guaranteed ignition
186-275 V
Emergency ballast lumen factor (EBLF) (nom.)
0.7 %
Nominal light output after 5 seconds
50% of EBLF
Approval and Application
Energy efficiency index
A2 BAT
EMI 9 kHz... 30 MHz
EN 55015 edition 7.1
EMI 30 MHz... 1,000 MHz
EN55022LEVELB
Safety standard
IEC 61347-2-3
Performance standard
IEC60929
Quality standard
ISO 9000:2000
Environmental standard
ISO14001
Harmonic current emission standard
IEC61000-3-2
EMC immunity standard
IEC 61547
Vibration standard
IEC68-2-6FC
Bumps standard
IEC 68-2-29 Eb
Humidity standard
EN61347-2-3CLAUSE11
Approval marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature marking
Yes
Emergency standard
IEC 60598-2-22
Humming and noise level
< 30 dB(A)
Product Data
Full product code
872790095230800
Order product name
HF-P 280 TL5/PL-L III 220-240V 50/60Hz
EAN/UPC – product
8727900952308
Order code
95230800
Local Code
HFP280T5PLLEIII
Numerator – quantity per pack
1
Numerator – packs per outer box
12
Material no. (12NC)
913713034366
Net weight (piece)
0.360 kg
Installation Diagrams
Performance Diagrams

Recently Viewed

    • Manage your projects with MyProjects
      Use MyProjects to create, save manage and share items and projects with you colleagues and team members.

Events    

 

 

Business Climate Summit

28-29.06.2016, London Guildhall

 

The Public Sector Show

28.06.2016, ExCeL

 

Grand Designs Live

19-23.10.2016, Birmingham NEC

 

View all events

You are now visiting our Global professional lighting website, visit your local website by going to the USA website